    TECHNICAL PARAMETERS
    Temperature measuring and operating range:
    -30 to +80°C
    Accuracy: ±0.4°C
    Applied sensor: Pt1000/3850ppm
    Break of sensor: >24mA
    Short circuit of sensor: <3.5mA
    Dimensions (W x H x D): approximately 89 x 151 x 37mm
    Protection: IP65
    Power: 9 to 30 V dc (typically 24V)
    Warranty: two years

    photo of transducer Px1x1

    Temperature transducer Px1x1

    Temperature transducers from Pt1000, Pt100 sensor to current 4-20mA

    TECHNICAL PARAMETERS
    Operating temperature:
    -30 to +80°C
    Break of sensor: >24mA
    Short circuit of sensor: <3.5mA
    Dimensions (W x H x D): approximately 89 x 123 x 37mm
    Protection: IP65
    Power: 9 to 30 V dc (typically 24V)
    Warranty: two years

    Available types of Pt1000 transducers, two-wire connection

    Typ Temperature range
    of 4-20mA output
    Accuracy of the input
    P4141 -100 to +30°C ±0.3°C
    P4121 -30 to +80°C ±0.3°C
    P4151 0 to +35°C ±0.2°C
    P4131 0 to +150°C ±0.3°C
    P4161 0 to +250°C ±0.4°C
    P4171 0 to +400°C ±0.7°C

    Transducers P41x1 are directly compatible with Comet temperature probes with the Pt1000 sensor with no connector - probe marking followed by /0 .

    Manual in pdfManual for P0120 and P41x1 in pdf format

    Available types of Pt100 transducers, two-wire, three-wire and two-wire with compensation loop connection

    Typ Temperature range
    of 4-20mA output
    Accuracy of the input
    P6181 -100 to +200°C ±0,3 °C up to +100°C,
    ±0,4°C over +100°C

    Manual in pdfManual for P6181 in pdf format

    Included is calibration certificate from the manufacturer.

    barometer wiring

    Typical application wiring

    Calculation of minimum power voltage Uss for proper operation:
    Uss min> Uo min + Imax * Rz,
    where: Uo min= 9 V
    Imax... approximately 20 mA
    Rz... sensing resistor (shunt)