    Data acquisition system MS5D, MS5

    Data acquisition system

    The complete solution for monitoring of temperature, humidity and other values especially in following applications:

    • Food and beverages industry (HACCP)
    • Pharmaceutical industry (GMP)
    • Blood stations, pharmacies
    • Horticulture and cultivation of plants
    • HVAC (heating, ventilation, air conditioning, cooling
    • Building and energy management
    • Research and development
    • Laboratories (GLP)

    Single-channel to sixteen-channel data loggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Datalogger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with ADAM Advantech protocol. Input signals are connected to removable terminal block located on the logger upper side. Analyzing of the record is enabled after data download to the personal computer by means of the included program via USB, RS232, Ethernet or GSM modem.

    Free program for monitoring system for Windows is ready to download.

    New generation data acquisition system especially enables:

    • to get information from data logger by means of the SMS messages - actual values, alarms, memory occupation and others - as response to SMS request from the user and after alarm creation at the logger. Data logger should be connected via GSM modem supporting SMS.
    • to configure individually each input channel for measurement, alarm evaluation and data logging, including individual data logging interval for each input.
    • each input channel can be individually programmed for different modes of record (continuous record, time dependent record, record only if specified logic conditions are matched, record triggered by external signal, etc.). It is enabled to record with shorter interval in case, measured values match previously defined conditions e.g. to map in detail trouble state. It is also enabled to memorize actual value and time if defined time event appears.
    • to set up to four different logic conditions for each channel to active alarm. Each condition compares measured values from inputs with set limits. It is possible to set hysteresis and delay of condition validity.
    • to assign to each input channel name of actual recorded process to identify monitored object (e.g. type of monitored product). It is enabled to select this name from data logger keyboard during the operation.
    • to indicate alarm state after matching defined combination up to four alarms from any inputs.
    • to store several configuration profiles (all logger parameters setting) for different measuring tasks and select profiles from logger keyboard.
    • Input signals are connected by means of the removeable terminal connector. Each input channel has three terminals - including shielding.

    Following data loggers are available:

    data logger - larger photo

    MS5D

    • fully equipped data logger
    • dual line alphanumerical LCD display
    • four control buttons
    • 32 alarm LEDs
    data logger - larger photo

    MS5

    • all functions as MS5D
    • without LCD display, without control buttons, without alarm LEDs
    • alarm is indicated by one common LED.
    TECHNICAL PARAMETERS OF DATA LOGGER
    Memory type: internal SRAM, backed-up by Lithium battery
    Total memory capacity: 2MB (up to 480 000 values)
    Data logging mode: noncyclic - logging stops after filling the memory
    cyclic - after filling memory oldest data is overwritten by new
    Data logging interval: adjustable individually for all input channels from 1 second to 24 hours
    Real time clock: year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
    Input measured values (1 to 16 inputs): are defined for each channel by installed input modules (see table) accordingly to user requirements
    Resolution of the AD converter (analog channels): 16 bits, conversion duration approximately 60ms/channel
    Supported interface for communication with computer:
    • RS232 (RxD,TxD,RTS,CTS,GND), cable up to 15 m - included. Enables direct connection with the PC or via line modem or GSM modem.
    • USB interface - included
    • RS485 - cable up to 1200 m, galvanically isolated, possibility of connection of several data loggers to one communication link - included
    • Ethernet interface LAN - optional
    Communication speed: 9600, 19200, 57600, 115200, 230400 Bd
    Outputs for alarm indication: 1) Red LED at the side of the case, 32 LEDs - only MS5D data logger
    2) Relay max. 8A/250Vac, switching-over contact
    3) Voltage signal 0V/4.8V, maximum current 50mA, output designed for connection of external audio indication unit or telephone voice dialer
    4) Alarm can be signalled also by e-mailu message, SNMP trap, SMS - please see optional accessory
    Power: 9 to 30Vdc, 24Vdc recommended
    Operating temperature range: 0 to +50°C
    Dimensions including connectors: 215 x 225 x 60 mm
    Protection: IP20
    Warranty: 2 years

    Communication interfaces:

    communication interfaces

    TYPES OF INPUTS
    TypeMeasured valueAccuracyNote
    A0 dc current 4 to 20 mA ±0.1% FS With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated.
    A1* dc current 4 to 20 mA ±0.1% FS for passive sensing of current
    B0* dc current 0 to 20mA ±0.1% FS  
    B1* dc current 0 to 1A ±0.1% FS  
    B2* dc current 0 to 5A ±0.1% FS  
    C0 ac current 0 to 20mA ±1% FS galvanic isolated
    C1 ac current 0 to 1A ±1% FS galvanic isolated
    C2 ac current 0 to 5A ±1% FS galvanic isolated
    D0* dc voltage 0 to 100mV ±0.1% FS  
    D1* dc voltage 0 to 1V ±0.1% FS  
    D2* dc voltage 0 to 10V ±0.1% FS  
    D5* dc voltage -10V to +10V ±0,1% FS
    (± 20 mV)

    New!

    D4* dc voltage 0 to 75V ±0.1% FS

    New!

    E0 ac voltage 0 to 100mV ±1% FS galvanic isolated
    E1 ac voltage 0 to 1V ±1% FS galvanic isolated
    E2 ac voltage 0 to 10V ±1% FS galvanic isolated
    E4 ac voltage 0 to 50V ±1% FS

    New!


    galvanically isolated
    F* measurement of resistance (specify the range) ±0.1% FS two-wire connection
    J* input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50 to 100°C ±0.2°C 100 to 250°C ±0.2% from reading  
    K* input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
    K1* input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
    K3 precise input for Platinum RTD temperature sensor Pt1000
    range -10 to +50°C
    ±0.06°C

    New!

    Two-wire connection.
    Only galvanically not isolated.
    N* thermocouple K (NiCr-Ni) range -70 to +1300°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
    T* thermocouple T (Cu-CuNi) range -200 to +400°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
    O* thermocouple J (Fe-Co) range -200 to 750°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
    P* thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±(0.3% + 1.5°C) from reading from +200 to +1700°C linearized, cold junction compensation
    Q* thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±(0.3% + 1°C) from reading from +300 to +1800°C linearized, without cold junction compensation
    S* binary input for potential-less contacts maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms
    S1 binary voltage input voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated
    CTU counter input for voltage signal voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated
    CTK counter input for potential-less contacts and open collector maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated
    FU input for measurement of frequency of voltage signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated
    FK input for measurement of frequency of contact switching 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated
    RS input for serial signal RS485 for devices supporting Advantech protocol e.g. measurement from transmitters with RS485 digital output connected to the serial RS485 network - ADAM Advantech protocol , galvanic isolated

    Input module for monitoring system

    Input module A0 4-20mA

    Input module for monitoring system

    Counter input module CTU

    Larger photo of monitoring system

    View of power and communication connectors

    Larger photo of monitoring system

    View of power and input connectors
    - three terminals/input

    Notes: Inputs marked ( * ) are not galvanic isolated and have common ground. These inputs are available also as galvanic isolated. Galvanic isolated analog inputs are marked with letter G following the name of input type (e.g. input for passive measurement of current 4-20mA - type A1 - with galvanic isolation is marked A1G). Galvanic isolation is not designed as safety protection.

    Included accessories:

    Calibration certificate from the manufacturer, communication cable for RS232, length 2 meters, free Windows program. Free program is available to dowload anytime. Program enables to control all logger functions and view and print the record in numerical format.

    OPTIONAL ACCESSORY
    Program for data acquisition for monitoring system SWR003 Optional software for Windows - comfort graphic environment data acquisition, including on-line graph, automatic data download and others
    Larger photo of monitoring system A1758 Universal ac/dc adapter 230V-50Hz/21Vdc/1A
    Larger photo of monitoring system A5948 Switching power source 230V-50Hz/24Vdc/30VA for DIN rail 35mm, triple terminals 24Vdc
    Monitoring system holder - larger photo MP013 Universal wall holders for data logger wall mounting
    Monitoring system holder - larger photo MP012 Holders for data logger mounting to DIN 35mm rail
    Cover of data logger connection cables
    M2007 Built-in LAN interface for data logger connection to Ethernet network. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses.



    MP010 Built-in independent SMS port for GSM modem connection for SMS reception and sending. Enables to receive information from data logger by means of SMS messages - actual values, alarms, memory occupation and others - as a response to SMS query from user or in case of alarm creation at data logger.
    Not necessary, if data logger is connected to the PC via GSM modem.
    Monitoring system converter - larger photo MP001 Converter RS485/RS232 for serial port COMx at the PC side, including ac/dc adapter
    Larger photo of data acquisition alarm M2002 external audio indication unit
    Larger photo of data acquisition alarm MP002 telephone voice dialer for alarm reporting, ac/dc adapter included
    MP016 External terminal with dual line alphanumerical LCD and control buttons and 32 alarm LEDs including interconnection cable - for panel mounting or mounting to a case lid. Identical functions as built-in terminal of MS5D data logger.
    MP018 Output relays module with interconnection cable. It contains 16 mains relays 250V/8A with switching-over contacts. Each relay can be control based on alarm creatione at different input channels accordingly to setting of user program. Output relays are designed for external devices control (switching of heating, cooling, ventilation, distant alarm etc.).
    Watertight case with cable glands
    Data logger modem - larger photo MP009 GSM modem WaveCom Fastrack M1306B, without accessories
    Data logger modem - larger photo MP009/1 antenna for GSM modem WaveCom Fastrack, right-angled
    MP009/2 communication cable for GSM modem Fastrack
    MP009/3 ac/dc adapter 230V/12V for GSM modem Fastrack
    Interior temperature, humidity, pressure transmitters Interior temperature, humidity, pressure transmitters with 4-20mA output
    Interior temperature, humidity, pressure transmitters Interior temperature, humidity, pressure transmitters serial RS485 output
    Barometer Barometer with 4-20mA output
    Photo of humidity transmitter humidity transmitters humidity and temperature transmitters with 4-20mA output
    Photo of temperature transmitter temperature transmitters programmable temperature transducers with 4-20mA output
    Photo of temperature transmitter temperature transmitters temperature transducers with 4-20mA output
    Photo of humidity transmitter humidity transmitters humidity and temperature transmitters with serial RS485 output
    Photo of temperature transmitter temperature transmitters temperature transmitters with serial RS485 output
    Photo of temperature probe Pt1000
    Photo of temperature probe Pt1000
    probes temperature probes with Pt1000/3850ppm sensor without connector - probe marking is followed by symbol /0